CR

COMPUTED RADIOGRAPHY

Computed Radiography (CR) is a digital imaging technology used in radiology to capture X-ray images without traditional film.

๐Ÿ” What is Computed Radiography?

Computed Radiography replaces conventional X-ray film with a special imaging plate (IP) inside a cassette. After exposure, the cassette is processed in a CR system to convert the image into a digital format.


โš™๏ธ How It Works

  1. X-ray Exposure โ†’ Image is captured on a phosphor imaging plate
  2. Cassette Processing โ†’ Inserted into CR reader
  3. Laser Scanning โ†’ Releases stored image data
  4. Digital Conversion โ†’ Image appears on computer screen
  5. Erasing Plate โ†’ Ready for reuse

๐Ÿงฉ Main Components

  • Imaging Plate (IP)
  • CR Cassette
  • CR Reader / Digitizer
  • Workstation (Computer & Software

KONICA MINOLTA

๐Ÿฅ KONICA REGIUS CR SYSTEM (Sigma II)

Best Overall (Clinic / Diagnostic Setup)

Konica Regius Sigma II CR System

๐Ÿ”ง Key Specifications

  • Compact desktop CR (only ~28 kg)
  • Throughput: up to 60 plates/hour
  • Resolution: 87.5 / 175 micron selectable
  • Image quality: 12-bit (4096 gray levels)
  • Cassette sizes: 8×10 to 14×17 inch
  • Software: ImagePilot (PACS + acquisition in one system)

โœ… Advantages

  • Very compact (ideal for small space clinics)
  • Low power consumption (~100VA)
  • High image quality (Konica processing technology)
  • Easy installation & maintenance

๐Ÿ–จ๏ธ KONICA THERMAL PRINTER (DRYPRO SERIES)

Recommended Model (Laser Imager)

ย 

Medical-grade thermal printer with DICOM connectivity and multi-film size support.

๐Ÿ”ง Key Features

  • Dry laser printing (no chemicals required)
  • Film sizes: 8×10 to 14×17 inch
  • DICOM compatible (direct PACS printing)
  • Speed: ~40โ€“50 films/hour
  • High contrast & diagnostic quality output

๐Ÿ“Š CR SYSTEM vs THERMAL PRINTER (WORKFLOW)

FunctionCR SystemThermal Printer
Image CaptureYesNo
Image ProcessingYesNo
Image PrintingNoYes
PACS IntegrationYesYes
Main RoleDigital ImagingHard Copy Output

๐Ÿ† Best Setup Recommendation

For a complete radiology setup:

๐Ÿ‘‰ REGIUS CR Sigma II + Drypro Thermal Printer = Full Digital + Film Output Solution

This combination is ideal for:

  • Diagnostic centres
  • Small & mid-size hospitals
  • Portable / semi-digital X-ray setups

๐Ÿ’ฐ Market Price (India Approx)

  • CR System: โ‚น3.5L โ€“ โ‚น7L (new/refurbished)
  • Thermal Printer: โ‚น4L โ€“ โ‚น5L

COMP.

Higher throughput CR system with faster plate processing for busy imaging centers.

โœ” Faster processing (~70+ plates/hour)
โœ” Suitable for high patient load


๐Ÿ“Š Product Comparison Table

Feature
ย 
Konica Regius Sigma II CR System
โ‚น6,54,250โ€ขMedikabazaar
ย 
Konica Regius 110 CR System
โ‚น3,50,000โ€ขTradeindia.com
ย 
Konica Drypro Laser Imager
โ‚น5,00,000โ€ขTradeindia.com
TypeCRCRThermal Printer
ThroughputUp to 60 plates/hrUp to ~70โ€“80 plates/hr~45 films/hr
Resolution87.5 ยตmHighHigh (print quality)
FunctionImagingImagingPrinting
Best ForClinicsHigh workload centersFilm output
Compact SizeYesMediumMedium

CARESTREAM

๐Ÿฅ CARESTREAM VITA FLEX CR SYSTEM (Best for Clinics)

Best Overall (Compact Digital CR)

Carestream Vita Flex CR System
ย 

๐Ÿ”ง Key Specifications

  • Throughput: 30 / 45 / 60 plates per hour
  • Cassette sizes: 8ร—10 to 14ร—17 inch
  • Orientation: Horizontal + Vertical (space-saving design)
  • Software: Image Suite (easy workflow + PACS ready)
  • Application: Clinic, hospital, mobile X-ray

โœ… Advantages

  • Compact & portable (ideal for small clinics)
  • Fast digital imaging (few minutes result)
  • Affordable digital upgrade (film to CR transition)
  • Supports long-length imaging & dental options

๐Ÿ–จ๏ธ CARESTREAM DRYVIEW LASER PRINTER

High-Quality Film Output

High-resolution medical laser printer with DICOM compatibility and multi-film size support.

๐Ÿ”ง Key Features

  • Dry laser technology (no chemicals required)
  • Resolution: ~325 dpi medical-grade imaging
  • DICOM connectivity (direct PACS printing)
  • Multiple film sizes (8×10, 10×12, 14×17)
  • High-speed printing (~40โ€“70 films/hour depending model)

โš™๏ธ COMPLETE WORKFLOW (CR + PRINTER)

  1. X-ray exposure โ†’ cassette
  2. Insert cassette into Vita Flex CR
  3. Image appears on workstation
  4. Send to DryView Laser Printer
  5. Get high-quality film output

๐Ÿ‘‰ This is called Capture-to-Print Solution


๐Ÿ“Š PRODUCT COMPARISON TABLE

Attribute
ย 
Carestream Vita Flex CR System
โ‚น7,00,000โ€ขRege Imaging & Cine Films
ย 
Carestream DryView 5950 Laser Imager
โ‚น17,50,000โ€ขHospital Store
FunctionImage Capture (CR)Film Printing
TechnologyPhosphor Plate + Laser ScanDry Laser Imaging
Throughput30โ€“60 plates/hr40โ€“70 films/hr
OutputDigital (DICOM)Hard Copy Film
SoftwareImage SuiteDICOM Compatible
Best UseClinics / Mobile setupsDiagnostic film output
Space RequirementVery compactMedium

๐Ÿ† Final Recommendation

  • Small clinic / startup โ†’ Vita Flex CR + DryView 5700
  • Mid-size diagnostic center โ†’ Vita Flex CR + DryView 5950
  • Mobile X-ray setup โ†’ Vita Flex CR (best due to compact size)

๐Ÿ‘‰ This combo is perfect alternative to Konica REGIUS + Drypro, slightly more budget-friendly and flexible.


๐Ÿ’ฐ Approx Price (India Market)

  • Vita Flex CR: โ‚น3L โ€“ โ‚น7L
  • DryView Printer: โ‚น2.5L โ€“ โ‚น15L (depends on model / refurb)

๐Ÿ”ฅ Pro Tip (for your business โ€“ Parbhriti Medical Systems)

ย